Copyright 1991 David Jurgens |
INT 67,4A - Get Logical to Physical Page Mapping (LIM EMS ≤ 3.0)
AH = 4A
DX = EMS handle
ES:DI far pointer to storage array
on return:
AH = 00 success
= error code (see EMS STATUS)
BX = contains count of entries placed in array at ES:DI
- defined in EMS 3.0, but undocumented in EMS 3.2; new software
should not use this function, but old software still works
- registers not listed are preserved
|
|