HelpPC 2.10 Quick Reference Utility Copyright 1991 David Jurgens

          INT 67,43 - Get Handle and Allocate Pages  (LIM EMS 3.2+)


       AH = 43h
       BX = number of logical pages to allocate


       on return:
       AH = 00  success
          = error code (see EMS STATUS)
       DX = EMM handle


       - handles not explicitly closed by the application are not
         recoverable on exit from the program
       - registers not listed are preserved

Esc or Alt-X to exit int 67,43 Home/PgUp/PgDn/End ←↑↓→
Converted to HTML in 2006 by Timo Bingmann